Electronic gear selection function

With the input devices CM1 (Electronic gear selection 1) and CM2 (Electronic gear selection 2), the numerator of the
electronic gear (CMX) can be selected. The electronic gear numerator (CMX) switches at the same time as CM1 and CM2 are
turned on or off. If a shock occurs at switching, use the position smoothing ([Pr. PB03 Position command speed adjustment
time constant (position smoothing)]) to relieve the shock.
*1
Input device
CM2
0
0
1
1
*1 0: Off
1: On
CM1
0
1
0
1
Electronic gear numerator
[Pr. PA06]
[Pr. PC32]
[Pr. PC33]
[Pr. PC34]
3.12 Electronic gear function [A]