■Speed feedback exceeded
During direction monitoring, the function monitors whether the speed is within the stop speed of the monitoring direction
specified by the speed feedback. If the time of the speed feedback remains exceeded for the duration set in [Pr. PSA15 Safety
sub-function - Speed detection delay time], the STO function is activated.
Servo motor speed
SDIPC (SDIP command)
SDIPS (SDIP output)
STOS (STO output)
Setting functional safety parameters
Refer to the following to set the functional safety parameters.
Page 431 Functional safety parameters that must be set
When using the safety sub-function control by input device, refer to the following.
Page 436 Input device
When using output devices, refer to the following.
Page 439 Output device
When using the safety sub-function control by network, refer to the following.
Page 442 Safety sub-function control by network
When using the SDI function, set the following parameters.
Parameter
PSA04
PSA15
PSA27
PSA28
6 FUNCTIONAL SAFETY
478
6.4 Safety sub-function
Stop speed
0 r/min
(mm/s)
Stop speed
ON (disabled)
OFF (enabled)
ON (disabled)
OFF (enabled)
ON
OFF (shut-off)
Name
Safety sub-function - Stop speed
Safety sub-function - Speed detection delay time
SDI positive direction monitor delay time
SDI negative direction monitor delay time
SDI positive direction
Direction monitoring
monitor delay time
Speed detection delay time
Feedback
Command
STO state