12.11 Firmware History - Endress+Hauser Proline Cubemass C 100 HART Operating Instructions Manual

Coriolis flowmeter
Table of Contents

Advertisement

Diagnostics and troubleshooting
Parameter
IP address
Subnet mask
Default gateway
94
Description
Displays the IP address of the Web server of
the measuring device.
Displays the subnet mask.
Displays the default gateway.

12.11 Firmware history

Release
Firmware
Order code
date
version
for
"Firmware
version"
04.2013 01.00.00
Option 76
06.2014 01.01.zz
Option 70
Flashing the firmware to the current version or to the previous version is possible via
the service interface (CDI) .
For the compatibility of the firmware version with the previous version, the installed
device description files and operating tools, observe the information about the device
in the "Manufacturer' s information" document.
The manufacturer' s information is available:
• In the Download Area of the Endress+Hauser Internet site: www.endress.com →
Download
• Specify the following details:
• Product root, e.g. 8E1B
• Text search: Manufacturer' s information
• Search range: documentation
User interface
4 octet: 0 to 255 (in the
particular octet)
4 octet: 0 to 255 (in the
particular octet)
4 octet: 0 to 255 (in the
particular octet)
Firmware
Documentation
changes
Original firmware
Operating
Instructions
• In accordance with
Operating
HART 7
Instructions
Specification
• Integration of
optional onsite
display
• New unit "Beer
Barrel (BBL)"
• Monitoring of
measuring tube
damping
• Simulation of
diagnostic events
• External
verification of the
current and PFS
output via the
Heartbeat
application package
• Fixed value for
simulation pulses
Proline Cubemass C 100 HART
Factory setting
192.168.1.212
255.255.255.0
0.0.0.0
Documentation
type
BA01188D/06/EN/01.13
BA01188D/06/EN/02.14
Endress+Hauser

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Proline Cubemass C 100 HART and is the answer not in the manual?

Questions and answers

Table of Contents