Endress+Hauser Proline Cubemass C 100 HART Operating Instructions Manual page 107

Coriolis flowmeter
Table of Contents

Advertisement

Proline Cubemass C 100 HART
Repeatability
Endress+Hauser
SI units
DN
1:1
[mm]
[kg/h]
1
20
2
100
4
450
6
1 000
US units
DN
1:1
[inch]
[lb/min]
¹⁄₂₄
0.735
¹⁄₁₂
3.675
¹⁄₈
16.54
¹⁄₄
36.75
Accuracy of outputs
The output accuracy must be factored into the measured error if analog outputs are
used, but can be ignored for fieldbus outputs (e.g. Modbus RS485, EtherNet/IP).
The outputs have the following base accuracy specifications.
Current output
Accuracy
Max. ±5 µA
Pulse/frequency output
o.r. = of reading
Accuracy
Max. ±50 ppm o.r. (over the entire ambient temperature range)
o.r. = of reading; 1 g/cm
3
Base repeatability
Design fundamentals →  109
Mass flow and volume flow (liquids)
±0.05 % o.r.
Mass flow (gases)
±0.25 % o.r.
Density (liquids)
±0.00025 g/cm
3
Temperature
±0.25 °C ± 0.0025 · T °C (±0.45 °F ± 0.0015 · (T–32) °F)
1:10
1:20
[kg/h]
[kg/h]
2
1
10
5
45
22.5
100
50
1:10
1:20
[lb/min]
[lb/min]
0.074
0.037
0.368
0.184
1.654
0.827
3.675
1.838
= 1 kg/l; T = medium temperature
Technical data
1:50
1:100
[kg/h]
[kg/h]
0.4
0.2
2
1
9
4.5
20
10
1:50
1:100
[lb/min]
[lb/min]
0.015
0.007
0.074
0.037
0.331
0.165
0.735
0.368
1:500
[kg/h]
0.04
0.2
0.9
2
1:500
[lb/min]
0.001
0.007
0.033
0.074