Application settings

The following shows the screen for the operation setting at event detection for a recorder module/camera recorder module.
Operation setting at event detection
Item
Error
Warning due to
Registration at
program change
Warning (Type:
during recording
System)
operation
Detection
Error (Type:
Error due to
System)
communication
*2
Detection
with a network
camera
*1 Can be set only when selecting "Main" for "Recording Operation Setting."
*2 Can be set only when using a camera recorder module.
*3 The combinations of target errors (error codes) and warnings (event codes) are as follows:
Error code
1D01
1DC0
1DF1
1E72
For details on the error codes and event codes, refer to the following:
Page 186 Error code list, Page 197 Event code list
2 PARAMETER SETTING
100
2.2 Module Parameters (Recorder Module/Camera Recorder Module)
Description
Set whether to register an error (continuation error) when a warning (type: system) is
detected due to a change in a program file or an FB/FUN file during recording
operation.
*1
[Warning due to program change during recording operation]
• Recording start with program inconsistency (event code: 0C00)
• Program change during recording operation (event code: 0C01)
Set whether to classify an event as an error or a warning when it occurs in the
communication with a network camera.
Event code
0D01
0DC0
0DF1
0E72
*3
Setting range
• Error is not registered
• Error is registered
(continuous error)
(Default: Error is not
registered)
• Error
• Warning
(Default: Error)