Mitsubishi Electric MELSEC iQ-R Series User Manual page 275

System recorder
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Buffer memory name
Recording status 1
Recording files saving count
Recording files saving progress
Recording files saving path (setting type
*1
folder)
Recording files saving path (under setting
type folder)
Recording startup trigger count
Invalid recording startup trigger
*1*2*3
count
File saving trigger count
Invalid file saving trigger count
Average device/label sampling
*1*2*4
interval
Address
*1
Un\G1511
*1
Un\G1514
Un\G1515 to 1522
Un\G1523 to 1555
*1*2
*1*2*3
Un\G1575
Un\G1576
*1*2*3
Un\G1577
*1*2*3
Un\G1578
Un\G1579 to 1580
7 CAMERA RECORDER MODULE (DETAILED SPECIFICATIONS)
Description
The number of recording file saving executions (both
successful and failed) is stored.
The definition of the number of saving executions differs
depending on the recording operation setting of a camera
recorder module used.
• Main module: Number of saving executions of recording
settings
• Sub module: Number of saving executions in the camera
recorder module itself
It is initialized to '0' when the operating status switches to
'operating' after turning the power ON or resetting a CPU
module and starting the recording function.
In addition, it is initialized to '0' when the operating status
switches to 'operating' after adding or changing a recording
setting and starting the recording function.
When it reaches 65535 times, it returns to 1 and continues
counting.
If it is reset, '0' is stored.
(Value to be stored: 0 to 65535)
The progress rate (%) of recording file saving is stored.
The definition of the progress rate differs depending on the
recording operation setting of a camera recorder module
used.
• Main module: Progress rate of recording file saving for all
recording settings including sub modules
• Sub module: Progress rate of recording file saving in the
camera recorder module itself
It is initialized to '0' when the operating status switches to
'operating' after a file saving trigger is satisfied or starting the
recording function.
(Value to be stored: 0 to 100%)
The path to the setting type folder for a recording file last
saved to an SD memory card is stored.
It is initialized to '0' when the operating status switches to
'operating' after a file saving trigger is satisfied or starting the
recording function.
(Example) When the path to a recording file is /SD/RECORD/
RC1/1TS01_001, /SD/RECORD/RC1/ is stored.
The path under the setting type folder to a last saved
recording file is stored.
It is initialized to '0' when the operating status switches to
'operating' after a file saving trigger is satisfied or starting the
recording function.
(Example) When the path to a recording file is /SD/RECORD/
RC1/1TS01_001, 1TS01_001 is stored.
When the operating status of the recording function is
'operating,' the number of times that a recording startup trigger
was detected to have been satisfied is stored.
(Value to be stored: 0 to 65535)
When the operating status of the recording function is
'operating,' the number of invalid recording startup triggers
among the recording startup triggers detected to have been
satisfied is stored.
(Value to be stored: 0 to 65535)
When the operating status of the recording function is
'operating,' the number of times that a file saving trigger was
detected to have been satisfied is stored.
(Value to be stored: 0 to 65535)
When the operating status of the recording function is
'operating,' the number of invalid file saving triggers among
the file saving triggers detected to have been satisfied is
stored.
(Value to be stored: 0 to 65535)
The average value of device and label sampling intervals is
stored (unit: millisecond).
It is calculated based on eight moving averages.
If an average value exceeds 4294967295 milliseconds,
4294967295 is stored.
7.4 Buffer Memory
7
273

Advertisement

Table of Contents
loading