■When specifying CPU stop error detection as a file saving trigger
If a stop error is detected in a CPU module, data accumulated before that is saved.
The following shows an operation when specifying CPU stop error detection as a file saving trigger.
(2)
(a)
(b)
(7)
(8)
(9)
(10)
(c)
(d)
(1) Time after recording starts
(2) Recording startup trigger
(3) A CPU stop error is detected.
(4) Running
(5) Saving
(6) Stopped
(7) Program operation
(8) END processing
(9) Scan time
(10) Sampling and accumulating
(11) Receiving and accumulating
(a) Operating status of the recording function
(b) Scan execution program
(c) Device and label
(d) Video data
: Data to be saved
*1 Data after a CPU stop error occurs is not saved.
■If the communication with a network camera is disconnected
For an operation in this case, refer to the following:
Page 20 If the communication with a network camera is disconnected
■Considerations
• The saving period must be set to a length sufficient to sample, receive, and accumulate changed data.
• If a file saving trigger is satisfied between when a recording startup trigger is satisfied and when a specified period elapses,
data for the specified period is saved to a save destination specified in the recording setting when it is accumulated.
(1)
(4)
(7)
(8)
(7)
(8)
(9)
(9)
(10)
(10)
(11)
(3)
(5)
(7)
*1
*1
(6)
1 FUNCTIONS
23
1.1 Recording Function
1