Mitsubishi Electric MELSEC iQ-R Series User Manual page 131

System recorder
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Filtering display
Displayed devices and labels can be filtered.
The following table shows filtering conditions that can be specified for each column.
Column
Device/Label
Sampling Target
Class
Label Data Type
Device
Range
Instruction
FB/FUN
Program File Name
Data Type
Data Name
Comment
■Filtering condition
A previously entered condition can be selected from the pull-down list.
A program file name and data name displayed in the list can also be selected in the "Program File Name" and "Data Name"
*2
columns.
In addition, conditions can be specified in multiple columns. In this case, only devices and labels that match all the conditions
are displayed.
*1 Up to 10 conditions are displayed in the following columns. If 11th one is entered, 10 conditions are displayed in order from an added
one. Note that the filter history is cleared when closing the project.
Device/Label
Class
Label Data Type
Device
Range
Instruction
FB/FUN
Comment
*2 Up to 50 conditions are displayed in the "Program File Name" and "Data Name" columns (up to 50 program file names and data names
in the list are displayed by default).
If 51st one is entered, 50 conditions are displayed in order from an added one. Note that the filter history returns to the default when
closing this screen or changing the selection status of the checkbox of "Include Devices/Labels Used in Parameter Setting" in the
"Setting" screen.
■Deleting a filtering condition
Filtering of a column can be cleared by deleting the keyword entered as a filtering condition for the column.
■Keywords for a filtering condition
The following table shows the wild cards that can be set as keywords in filtering conditions to search for a character string.
Wild card
Target
*
Any character string
?
Any one character
[ ]
Any one of specified characters
■Case in which an error occurs
'[' and ']' are not paired.
(Example) X[0, X1]
Description
Any characters can be specified (up to 32 characters).
Either of the following items can be selected:
• Enable (Sampling Target)
• Disable (Sampling Target Excluded)
Any characters can be specified (up to 32 characters).
Any of the following items can be selected:
• Program
• FB
• CPU Parameter
• Module Parameter
• Block Information
Any characters can be specified (up to 32 characters).
Any characters can be specified (up to 32 characters).
*1*2
Example
Result
*D30*
red301, @D30, XD30, D30, D30:U
K4?30
K4X30, K4Y30
[XY]8
X8, Y8
3.3 Device/Label Sampling Setting
3 RECORDING SETTING
129
3

Advertisement

Table of Contents
loading

Table of Contents