Recording setting information area (Un\G3200 to 3999)
Setting information of recording settings can be checked.
Buffer memory name
Recording setting
Recording buffer size
*1
information 1
Saving period
Saving setting when there is no free
folder number
Recording startup trigger specification
Recording startup trigger establishment
condition
Saving specification after the specified
time has elapsed from recording
completion
Waiting time from recording completion
to file saving
Establishment condition of file saving
trigger
Recording files saving destination
Camera event trigger settings
Recording
buffer size
(video data)
Saving specification when CPU stop
error is detected
*2
*2
*3
*4
Network camera 1
Network camera 2
Network camera 3
Network camera 4
Address
Description
Un\G3200
The recording buffer capacity set in the module parameter is
stored (unit: MB).
Un\G3201 to 3202
A saving period set in the recording setting is stored.
(Unit: second)
■When selecting "File Saving Trigger Only" for the recording
method
Total saving period before and after trigger
■When selecting "Recording Startup Trigger + File Saving
Trigger" for the recording method
Accumulation period
Un\G3203
A saving setting when there is no free folder number set in the
recording setting is stored.
0: Overwrite
1: Not save
Un\G3204
A recording startup trigger specification set in the recording
setting is stored.
0: Not specify (when selecting "File Saving Trigger Only" for
the recording method)
1: Specify (when selecting "Recording Startup Trigger + File
Saving Trigger" for the recording method)
Un\G3205
The condition for satisfying a recording startup trigger set in
the recording setting is stored in b0.
OFF: Rising
ON: Falling
Un\G3206
The saving specification after the specified time has elapsed
from recording completion set in the recording setting is
stored.
0: Not specify
1: Specify
Un\G3207 to 3208
The waiting time from recording completion to file saving set in
the recording setting is stored (unit: second).
Un\G3209
The condition for satisfying a file saving trigger set in the
recording setting is stored.
*5
OFF: Rising
ON: Falling
Un\G3210
The save destination for a recording file set in the recording
setting is stored.
0: SD memory card
1: File server
Un\G3211
Whether a camera event that occurs in each network camera
is applied as a condition for satisfying a file saving trigger is
stored. (0: Disabled/1: Enabled)
b0: Network camera 1
b1: Network camera 2
b2: Network camera 3
b3: Network camera 4
Un\G3213
The recording buffer capacity (MB) set for network camera 1
in the recording setting is stored.
The total value of the recording buffer capacities of network
cameras 1 to 4 is equal to a value of the recording buffer
capacity (video data) assigned to the corresponding setting
number set in the module parameter.
Un\G3214
Details are the same as network camera 1.
Un\G3215
Un\G3216
Un\G3250
The saving specification when a CPU stop error is detected
set in the recording setting is stored.
0: Not specify
1: Specify
7 CAMERA RECORDER MODULE (DETAILED SPECIFICATIONS)