Device name (device)
Link direct
Link input (Jn\X)
*1
device
Link output (Jn\Y)
Link relay (Jn\B)
Link register (Jn\W)
Link special relay
*2
(Jn\SB)
Link special register
*3
(Jn\SW)
Safety user
Safety input (SA\X)
*4
device
Safety output (SA\Y)
Safety internal relay
*2
(SA\M/SA\#M)
Safety link relay
*2
(SA\B)
Safety link register
*3
(SA\W)
Safety timer (SA\T/
SA\#T)
Safety retentive timer
(SA\ST/SA\#ST)
Safety counter (SA\C/
SA\#C)
Safety data register
*3
(SA\D/SA\#D)
Safety system
Safety special relay
*4
*2
device
(SA\SM)
Safety special register
*3
(SA\SD)
Other devices
Step relay with block
specification (BL\S)
*1 Cannot be sampled when selecting "Safety Cycle Time" for "Sampling Method."
*2 When the number of device points is set to 512 points or less in the CPU parameter, the set number of points is sampled (the minimum
is 64 points (bits)).
*3 When the number of device points is set to 32 points or less in the CPU parameter, the set number of points is sampled (the minimum is
4 points (words)).
*4 Can be sampled only when using a safety CPU.
*5 Neither local index register nor local long index register can be specified.
When specifying either of them in a program, an index register or a long index register is sampled as a global device.
In addition, 32-bit index modification with ZZ expression cannot be specified.
*6 When using 'include SFC device' of 'device/label batch specification,' information for the system is also sampled for displaying a
program for monitoring in an SFC diagram on the offline monitor. (Page 40 When using 'include SFC device' of 'device/label batch
specification')
SFC block devices (BL) in a ladder program or Zoom can be monitored only when selecting the above method.
Sampling unit
Size (word)
(point)
*2
512
32
*2
512
32
*2
512
32
*3
32
32
512
32
32
32
*2
512
32
*2
512
32
512
32
512
32
32
32
32
36
32
36
32
36
32
32
512
32
32
32
1
1
*6
Remarks
• When specifying an SA\T, a contact (SA\TS), coil (SA\TC),
and current value (SA\TN) are sampled.
• Even when specifying an SA\TS, SA\TC, or SA\TN
individually, all of them are sampled.
• When specifying an SA\ST, a contact (SA\STS), coil
(SA\STC), and current value (SA\STN) are sampled.
• Even when specifying an SA\STS, SA\STC, or SA\STN
individually, all of them are sampled.
• When specifying an SA\C, a contact (SA\CS), coil
(SA\CC), and current value (SA\CN) are sampled.
• Even when specifying an SA\CS, SA\CC, or SA\CN
individually, all of them are sampled.
The start device is a multiple of 16 points, and the end device
is variable in one bit units.
1 FUNCTIONS
1.1 Recording Function