Mitsubishi Electric MELSEC iQ-R Series User Manual page 26

System recorder
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

(1)
(3)
(4)
(6)
(7)
(1) Recording startup trigger
(2) File saving trigger
(3) Device and label
(4) Sampling
(5) Sampling and accumulating
(6) Video data
(7) Receiving and accumulating
(8) Receiving
(9) Time
(a) Set saving period
(b) Saving period
(c) Period during which a recording file is saved
• When switching a CPU module from RUN to STOP or stopping the recording function in the "Recording Monitor" screen or
if a CPU stop error occurs in the CPU module between when a file saving trigger is satisfied and when a specified period
elapses, data accumulated before the stop is saved. (Page 143 RECORDING MONITOR)
• Due to the time accuracy of a recorder module/camera recorder module, an error occurs between a set saving period and
an actual one. For the time accuracy, refer to the following:
MELSEC iQ-R System Recorder User's Manual (Startup)
1 FUNCTIONS
24
1.1 Recording Function
(2)
(5)
(4)
(8)
(a)
(c)
(b)
(9)

Advertisement