Tool Setting - Advantech VisionNavi User Manual

Table of Contents

Advertisement

cution).
<<Point>>
It is recommended to perform white balance adjustment in the following situations.
When the color camera is first installed
When replacing the color camera
When the color tone (RGB balance) of white illumination has changed
Measurement tool
Simple distance measurement can be performed by using the measurement tool.
When the Measurement Tool is selected and the Camera Setting Tool is displayed,
the current measurement position is reflected in the measure.
Guideline display tool
By displaying the guidelines, you can adjust the imaging position and tilt. Click the
[Guideline Display] icon to change the display mode.

Tool setting

Tool setting menu
By right clicking on the tool list, you can display the tool setting menu and make set-
tings.
Add new tool below
Add a new tool under the selected tool.
Copy this tool / Paste the tool / Copy all tools
You can copy the selected tool and paste it at an arbitrary place.
Delete this tool / Delete all tools
Delete selected tool or all tools.
Set the execute condition
Each tool can be set to execute only when the specified condition is met.
Right-click on the tool →set the execution condition and select the menu.
Always valid ··The tool will always run.
Invalid ··········The tool will not run.
Only once after reset ···Execute the tool only once after startup or after detecting
reset input.
Execute when the result of previous tool was OK / NG.
···················The tool is executed only when the result of the previous tool was OK /
NG.
If the previous tool was running
···················The tool runs only when the previous tool was executed.
If the previous tool was not running
···················The tool runs only when the previous tool was not executed.
If it is the specified variable
···················The tool is executed only when the branch variable is set to a specific
value.
In running mode only
···················It is not executed in the setting mode, and the tool is executed only in
the running mode.
If the overall judgement is OK / NG
···················The tool is executed only when the overall judgment result up to the
previous tool is OK / NG.
Reflect the result to overall judgement
Choose whether to reflect the judgment result of the tool on the overall judgment
result.
Tool name / Edit the tool comment
Edit tool name / comment.