Advantech VisionNavi User Manual page 71

Table of Contents

Advertisement

If you set the timeout time, processing will be executed regardless of the state of the
monitoring target after that time elapses. Tool judgment result is NG. If you set the
timeout time to -1, the timeout will be invalid.
Synchronization
When operating the camera in synchronous mode (independent control OFF), issue
camera synchronization event and synchronize with other cameras.
You can accept synchronization events by selecting [Sync event monitoring] in the
status monitoring tool.
Processing condition
[Camera ID]
CAM_ALL ·····Synchronization events are issued to all cameras.
CAM1 〜 CAM7 ·····A synchronization event is issued to the specified camera.
End operation
Finish the processing flow.
Combined with the execution condition judgment function, you can finish processing
under specific conditions and end all processing, or move to the beginning of the tool
list.
Processing condition
[End option]
End all programs ············Finish driving by inspection project.
Continue from the first tool
···················Return to the top of the tool list without processing the remaining tools.
Display dialog
Display arbitrary comments and accept input from the user by displaying a dialog
box.
Processing condition
[Display button]
OK ··············Only the character string and OK button are displayed. OK is always
returned as the judgment result of the tool.
OK/NG ·········When NG is selected, NG is returned as the judgment result of the
tool.
End / Resume
···················When End is selected, all driving by the inspection project will be termi-
nated.
Input value to DM (Integer / Decimal)
···················Assign an arbitrary numerical value (integer or decimal number) to
DM.
Input string to DM
···················Assign an arbitrary character string to DM.
65