Measure width
Measure the width of the work and groove.
Detect condition
[Edge dir.]
Same direction
···················Automatically set " Dark -> Light" or " Light -> Dark".
Dark -> Light
···················Only edges that change from a dark pixel to a light pixel are detected.
Light -> Dark
···················Only edges that change from a light pixel to a dark pixel are detected.
[Measure interval] , [Width 1, 2]
[Edge strength]
The threshold to detect as an edge when the most clear edge in the target part is
100. It is possible to adjust to a stable value while referring to the edge intensity dis-
tribution.
[Filter (sigma)]
The strength of the filter which cancels the noise component.
[Integrity]
The ratio of the extraction points necessary for contour generation. When set to 1, it
is necessary to obtain extraction points in all the cells of the outline extraction guide
frame. By lowering the value, it is possible to extract even if the contour is discounti-
nous.
[Distance th]
47