Function List - Mitsubishi Electric MELSERVO MR-J3-xT Instruction Manual

Servo amplifier
Table of Contents

Advertisement

1. FUNCTIONS AND CONFIGURATION
Servo Amplifier
Item
During
operation
Ambient
temperature
In storage
Ambient
In operation
humidity
In storage
Ambient
Altitude
Vibration
Mass
Note 1. 150mA is the value applicable when all I/O signals are used. The current capacity can be decreased by reducing the number of
I/O points.
2. When closely mounting the servo amplifier of 3.5kW or less, operate them at the ambient temperatures of 0 to 45
or smaller effective load ratio.

1.3 Function list

The following table lists the functions of this servo. For details of the functions, refer to the reference field.
Function
Positioning by automatic operation
Varied speed operation
Automatic continuous positioning
operation
Home position return
High-resolution encoder
Absolute position detection system
Gain changing function
Advanced vibration suppression
control
Adaptive filter
Low-pass filter
Machine analyzer function
Machine simulation
Gain search function
Slight vibration suppression control Suppresses vibration of 1 pulse produced at a servo motor stop.
10T 20T 40T 60T 70T 100T 200T 350T 500T 700T 11KT 15KT 22KT 10T1 20T1 40T1
MR-J3-
[ ] (Note 2) 0 to 55 (non-freezing)
[ ] 32 to 131 (non-freezing)
[ ]
20 to 65 (non-freezing)
[ ]
4 to 149 (non-freezing)
90%RH or less (non-condensing)
Indoors (no direct sunlight)
Free from corrosive gas, flammable gas, oil mist, dust and dirt
Max. 1000m (3280ft) above sea level
2
5.9 [m/s
] or less
[kg] 0.8 0.8 1.0 1.0 1.4
[lb] 1.8 1.8 2.2 2.2 3.1
Select the required ones from among 31 preset point tables and perform
operation in accordance with the set values.
Use the external input signal or communication function to choose the point
tables.
Servo motor speed can be varied continuously until the preset moving
distance is reached. (Max. set speeds: 255 speeds)
By merely choosing one point table and starting operation, positioning can
be executed continuously in accordance with several point tables.
Dog type, count type, data setting type, stopper type, home position
ignorance, dog type rear end reference, count type front end reference, dog
cradle type
High-resolution encoder of 262144 pulses/rev is used as a servo motor
encoder.
By merely setting the home position once, home position return need not
be done at each power on.
You can switch between gains during rotation and gains during stop or use
an external signal to change gains during operation.
This function suppresses vibration at the arm end or residual vibration.
Servo amplifier detects mechanical resonance and sets filter characteristics
automatically to suppress mechanical vibration.
Suppresses high-frequency resonance which occurs as servo system
response is increased.
Analyzes the frequency characteristic of the mechanical system by simply
connecting a servo configuration software-installed personal computer and
servo amplifier.
MR Configurator MRZJW3-SETUP221E is necessary for this function.
Can simulate machine motions on a personal computer screen on the basis
of the machine analyzer results.
MR Configurator MRZJW3-SETUP221E is necessary for this function.
Personal computer changes gains automatically and searches for
overshoot-free gains in a short time.
MR Configurator MRZJW3-SETUP221E is necessary for this function.
1.4
2.3
2.3
4.6
6.2
3.1 5.071 5.071 10.1 13.7 39.68 39.68 41.88
Description
1 - 9
18
18
19
0.8
0.8
1.8
1.8
or at 75%
Reference
Section 5.4
Section 5.4.2 (4)(b)
Section 5.4.2 (4)
Section 5.6
Section 5.7
Section 10.6
Section 10.4
Section 10.2
Section 10.5
Parameters No.
PB24
1.0
2.2

Advertisement

Table of Contents
loading

Table of Contents