Point Table Error - Mitsubishi Electric MELSERVO MR-J3-xT Instruction Manual

Servo amplifier
Table of Contents

Advertisement

11. TROUBLESHOOTING
Display
Name
AEC
Overload warning
2
AED
Output watt excess
warning

11.5 Point table error

When a point table error occurs, the parameter error (A37) occurs. After the parameter No. of parameter error
(37), the point table error details are displayed.
Definition
Operation, in which a
During a stop, the status in which a current
current exceeding the
flew intensively in any of the U, V and W
rating flew intensively in
phases of the servo motor occurred
any of the U, V and W
repeatedly, exceeding the warning level.
phases of the servo
motor, was repeated.
The status, in which the
Continuous operation was performed with
output wattage (speed
the output wattage (speed
torque) of the servo motor
servo motor exceeding 150% of the rated
exceeded the rated
output.
output, continued steadily.
A L 3 7
# 0 0
P B 1 0
P B 1 1
P B 1 2
P B 1 6
P o s 0 0 1
Point table error details
For the point table No.1 position data error
Point table No. with error
Error item
Pos: position data
Spd: speed
Acc: acceleration time constant
Dec: deceleration time constant
Dwl: dwell
Aux: auxiliary function
Cause
torque) of the
11 - 12
Action
1. Reduce the positioning
frequency at the specific
positioning address.
2. Reduce the load.
3. Replace the servo amplifier/
servo motor with the one of
larger capacity.
1. Reduce the servo motor
speed.
2. Reduce the load.

Advertisement