Mitsubishi Electric MELSERVO MR-J3-xT Instruction Manual page 123

Servo amplifier
Table of Contents

Advertisement

4. SIGNALS AND WIRING
(b) Termination of the cables
1) CNP1 CNP3
Solid wire: After the sheath has been stripped, the cable can be used as it is.
Twisted wire: Use the cable after stripping the sheath and twisting the core. At this time, take care to avoid
a short caused by the loose wires of the core and the adjacent pole. Do not solder the core as
it may cause a contact fault. Alternatively, a bar terminal may be used to put the wires
together.
Cable size
[mm
1.25/1.5
2.0/2.5
2) CNP2
CNP2 is the same as MR-J3-100T or smaller capacities. Refer to (1) (b) of this section.
(c) As twin type connector for CNP2 (L
Refer to (1) (C) of this section.
2
]
AWG
For 1 cable
16
AI1.5-8BK
14
AI2.5-8BU
, L
11
Sheath
Core
7mm
Bar terminal type
For 2 cables
AI-TWIN2 1.5-8BK
AI-TWIN2 2.5-10BU
) is the same as MR-J3-100T or smaller.
21
4 - 13
Crimping tool
CRIMPFOX-ZA3
Phoenix Contact
Maker