Test Operation Mode - Mitsubishi Electric MELSERVO MR-J3-xT Instruction Manual

Servo amplifier
Table of Contents

Advertisement

8. PARAMETER UNIT (MR-PRU03)

8.5.7 Test operation mode

CAUTION
Exiting test/JOG operation/positioning operation/motor-less operation/DO forced stop/single-step feed can be
performed in this mode. The following shows how to set each operation.
When the servo motor equipped with electromagnetic brake is used, make sure to program a sequence circuit
which will operate the electromagnetic brake by the servo amplifier electromagnetic brake interlock (MBR).
When confirming the machine operation in the test operation mode, use the
machine after checking that the safety mechanism such as the forced stop (EMG)
operates.
If any operational fault has occurred, stop operation using the forced stop (EMG).
POINT
The test operation mode cannot be used in the absolute position detection
system. Use it after choosing "
Test operation cannot be performed if the servo-on signal is not turned OFF.
TEST
0" in parameter No. PA03.
JOG operation
Positioning operation
Motor-less operation
DO forced output
Single-step feed
8 - 15