Home Position Return Automatic Return Function - Mitsubishi Electric MELSERVO MR-J3-xT Instruction Manual

Servo amplifier
Table of Contents

Advertisement

5. STARTUP

5.6.13 Home position return automatic return function

If the current position is at or beyond the proximity dog in the home position return using the proximity dog, this
function starts home position return after making a return to the position where the home position return can be
made.
(1) When the current position is at the proximity dog
When the current position is at the proximity dog, an automatic return is made before home position return.
Makes an automatic return to a position
before the proximity dog, then executes
home position return at this position.
(2) When the current position is beyond the proximity dog
At a start, a motion is made in the home position return direction and an automatic return is made on
detection of the strok end (LSP or LSN). The motion stops past the front end of the proximity dog, and
home position return is resumed at that position. If the proximity dog cannot be detected, the motion stops
on detection of the LSP or LSN switch and A90 occurs.
Makes an automatic return to a position
before the proximity dog, then executes
home position return at this position.
Software limit cannot be used with these functions.
Home position return direction
Home position return direction
Proximity dog
Home position return
start position
Proximity dog
Home position return
start position
5 - 52
Strok end
(LSP or LSN)

Advertisement

Table of Contents
loading