Juniper EX2300 Series Hardware Manual page 68

Hide thumbs Also See for EX2300 Series:
Table of Contents

Advertisement

Table 19: EX Series Switch Environmental Tolerances
Switch or
Environment Tolerance
device
Altitude
No performance
EX4600
degradation to
6,562 feet
(2000 meters)
EX4650
No performance
degradation to
6,000 feet
(1829 meters)
EX6210
No performance
degradation up to
10,000 feet
(3048 meters)
(Continued)
Relative Humidity
Normal operation
ensured in the relative
humidity range 5%
through 90%,
noncondensing
Short-term
operation ensured in
the relative humidity
range 5% through
93%, noncondensing
NOTE: As defined in
NEBS GR-63-CORE,
Issue 4, short-term
events can be up to
96 hours in duration
but not more than
15 days per year.
Normal operation
ensured in the relative
humidity range 10%
through 85%
(condensing)
Normal operation
ensured in the relative
humidity range 10%
through 85%
(noncondensing)
Temperature
Normal operation
ensured in the
temperature range 32°
F (0° C) through 113°
F (45° C)
Nonoperating storage
temperature in
shipping container: –
40° F (–40° C)
through 158° F
(70° C)
Normal operation is
ensured in the
temperature range 32° F
(0° C) through 104° F
(40° C)
Normal operation is
ensured in the
temperature range 32° F
(0° C) through 104° F
(40° C)
Seismic
Complies with
Zone 4
earthquake
requirements per
NEBS GR-63-
CORE, Issue 4.
Complies with
Zone 4
earthquake
requirements as
per GR-63, Issue
4.
Complies with
Zone 4
earthquake
requirements as
per GR-63, Issue
4.
59

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents