Table 37: Parts Required for Connecting an EX Series Switch to Earth Ground
Switch
Earthing
Terminal
Location
EX3200,
Rear panel of
EX3300,
the chassis
and
EX3400
EX4200,
Left side of
EX4500,
the chassis
and
EX4550
EX6210
Rear panel of
the chassis
(on lower left
side)
Grounding
Grounding Lug
Cable
Specifications
Requirements
14 AWG
Panduit
(2 mm²),
LCC10-14BWL or
minimum 90° C
equivalent—
wire, or as
not provided
permitted by
the local code
14 AWG
Panduit
(2 mm²),
LCC10-14BWL or
minimum 90° C
equivalent—
wire, or as
not provided
permitted by
the local code
The grounding
Panduit LCD2-14A-
cable must be
Q or equivalent
the same gauge
—provided
as the power
feed cables and
as permitted by
the local code.
(Continued)
Screws and
Additional
Washers
Information
For EX3200
Two
Switches, see
10-32 x .25 i
"Special Instructions
n. screws
to Follow Before
with #10
Connecting Earth
split-lock
Ground to an EX
washer—
Series Switch" on
not provided
page
139.
Two #10 flat
washers—
not provided
See
"Special
Two 10-32
Instructions to
x .25 in.
Follow Before
screws with
Connecting Earth
#10 split-
Ground to an EX
lock washer
Series Switch" on
page
139.
not provided
Two #10 flat
washers—
not provided
Two ¼ -20
x 0.5 in.
screws with
#¼" split-
washer
—provided
Two #¼" flat
washers—
provided
136