Airflow Direction in EX2300 Switches without PoE Capability
Figure 38 on page 45
shows the airflow in EX2300 switches without PoE capability.
Figure 38: Airflow Direction in EX2300 Switches with 24 Ports without PoE Capability
Under normal operating conditions, the fans operate at a moderate speed to reduce noise. Temperature
sensors in the chassis monitor the temperature within the chassis. If any fan fails or if the temperature
inside the chassis rises above the threshold, the switch raises an alarm and all functioning fans operate
at a higher speed than normal. If the temperature inside the chassis rises above the threshold, the switch
shuts down automatically.
RELATED DOCUMENTATION
Understand Alarm Types and Severity Levels on EX Series Switches | 231
Clearance Requirements for Airflow and Hardware Maintenance for EX2300 Switches | 67