Juniper EX2300 Series Hardware Manual page 132

Hide thumbs Also See for EX2300 Series:
Table of Contents

Advertisement

c. Mark a point P at a distance of 4.3 in. (10.9 cm) on a level line to the right from hole B.
d. Drill a hole C at a distance of 3.78 in. (9.6 cm) on a level line to the top from point P and install a
mounting screw.
4. Place the switch against the wall such that the front panel of the switch faces to the right side and
the holes on the bottom panel of the switch align with the mounting screw heads.
5. Slide the switch chassis to the left or right a bit so that the mounting screws are pushed into the
channels of the holes on the bottom panel until the switch rests firmly in place as shown in
6. Slide the switch chassis to the left or right a bit so that the mounting screws are pushed into the
channels of the holes on the bottom panel until the switch locks firmly in place as shown in
15.
Figure 64: Mounting an EX2300-C Switch on a Wall
7. (Optional) Attach the optional standard cable lock to the security slot on the side of the switch:
a. Fasten the cable to a desk or a rack and set the lock to the unlocked position.
123
Figure
15.
Figure