YASKAWA CC-Link SI-C3 Installation Manual page 45

Ac drive option
Hide thumbs Also See for CC-Link SI-C3:
Table of Contents

Advertisement

Signal
Name
Digital Output 2
*1
Function
1000-Series, GA500:
Terminal P2
*1
Function
RX7
GA700, GA800:
Multi-Function
Digital Output 3
*1
Function
RX8, 9
Reserved
CC-Link Option
RXA
Fault
Monitoring Motor
RXB
Revolutions
RXC
Obtain Monitor Data ON: Monitor data has been updated.
Frequency Setting
RXD
Ready 1
Frequency Setting
RXE
Ready 2
Command Code
RXF
Execute Complete
RX10 -
Reserved
19
RX1A
Error
Remote Station
RX1B
Ready
RX1C -
Reserved
1F
*1
Terminals are different for different drive models. Refer to
of the Drive on page 53
YASKAWA TOEP C730600 83A CC-Link Installation Manual
Description
Multi-Function Output: H2-03
Communication error between drive and CC-Link
device
ON: Currently monitoring motor revolutions.
ON: Displays the main frequency reference that has
been set.
ON: Displays the data set to d1-01 [Frequency
Reference 1].
Note:
Also sets the main frequency reference at the same
time.
ON: Displayed after the specified command code has
been executed.
RXF signal switches OFF when the RYF command is
no longer present.
ON: Fault occurred on the drive side.
ON: Drive is ready to operate.
for more information.
-
-
-
Terminals that Change depending on the Model
8 CC-Link Data List
Comments
(Default)
GA500: H2-02 =0
[Terminal P1-C1
Function Selection
During Run]
1000-Series, GA700,
GA800: H2-03 = 2
[Term M5-M6
Function Selection =
Speed Agree 1]
GA500: H2-03 = 2
[Terminal P2-C2
Function Selection =
Speed Agree 1]
-
-
Data is stored in
remote register
RW
.
R1
-
-
-
-
-
-
-
-
45