[Minimum Cycle Time (Obj. 1C33h: 05h)]

Data Type
Access
U32
RO
Description
The minimum communication cycle is returned.
Servo amplifier
MR-J5-_G-_N1
MR-J5W_-_G-N1

[Calc and Copy Time (Obj. 1C33h: 06h)]

Data Type
Access
U32
RO
Description
The minimum value of the delay time from data inputting to transmitting is returned. The received value varies depending on
the setting of the communication cycle.

[Delay Time (Obj. 1C33h: 09h)]

Data Type
Access
U32
RO
Description
The delay time from Sync0 to input is returned. The received value varies depending on the setting of the communication
cycle.

[Cycle Time Too Small (Obj. 1C33h: 0Ch)]

Data Type
Access
U16
RO
Description
"0" is returned.
Mapping
Default
Impossible
Minimum communication cycle
125000
250000
Mapping
Default
Impossible
Mapping
Default
Impossible
0
Mapping
Default
Impossible
0
Range
Units
ns
Range
Units
ns
Range
Units
0 (fixed)
ns
Range
Units
0 (fixed)
ns
4 Sync Manager Communication Objects
4.5 [SM input parameter (Obj. 1C33h)]
Save
Parameter
Impossible
Save
Parameter
Impossible
Save
Parameter
Impossible
Save
Parameter
Impossible
4
41

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo mr-j5-g-n1 seriesMelservo mr-j5w-g-n1 series

Table of Contents