[Pr. Pc24_Deceleration Time Constant At Forced Stop (Rsbr)]; [Pr. Pc26_Function Selection C-8 (**Cop8)] - Mitsubishi Electric MR-J5-G User Manual

Hide thumbs Also See for MR-J5-G:
Table of Contents

Advertisement

[Pr. PC24_Deceleration time constant at forced stop (RSBR)]

Initial value
100 [ms]
Set the deceleration time constant for the forced stop deceleration function.
Set the time taken from the rated speed to 0 [r/min] (0 [mm/s]) in units of ms.
When "0" is set, the deceleration time constant is the same as when "100" is set.
Rated speed
Servo motor speed
This servo parameter corresponds to [Quick stop deceleration (Obj. 6085h)]. When the object is mapped to the cyclic
communication, do not write values with engineering tools because the controller overwrites the servo parameter values
written with engineering tools.
This servo parameter is enabled when [Pr. PT01.1 Speed/acceleration/deceleration unit selection] is set to "0". This servo
parameter and [Pr. PV09 Deceleration at forced stop] are mutually exclusive.
• If the servo motor torque or thrust is saturated at the maximum value during forced stop deceleration because the set time
is too short, the time to stop the servo motor will be longer than the set time constant.
• [AL. 050 Overload 1] or [AL. 051 Overload 2] may occur during forced stop deceleration, depending on the set value.
• After an occurrence of an alarm to execute forced stop deceleration, if another alarm that does not execute forced stop
deceleration occurs, or if the control circuit power supply is shut off, dynamic braking will start regardless of the deceleration
time constant setting.
• Set a longer time than deceleration time at quick stop of the controller. If the setting time is too short, [AL. 052 Excessive
error] may occur.
• During forced stop deceleration, changes in the setting value are not reflected. If the setting value is changed during forced
stop deceleration, the change will be reflected after the deceleration is completed.

[Pr. PC26_Function selection C-8 (**COP8)]

Initial value
00000050h
[Pr. PC26.3_Load-side encoder cable communication method selection]
Initial value
0h
0: Two-wire type
1: Four-wire type
When using a load-side encoder that is A/B/Z-phase differential output type, set "0". Setting "1" triggers [AL. 037 Parameter
error].
If the value is set incorrectly, [AL. 070 Load-side encoder initial communication error 1] or [AL. 071 Load-side encoder normal
communication error 1] occurs.
Setting "1" on servo amplifiers other than the MR-J5-_G_-RJ and MR-J5D1-_G_ triggers [AL. 037].
Setting range
0 to 20000
Forced stop deceleration
Dynamic brake deceleration
Zero speed
[Pr. PC24]
Setting range
Refer to the relevant detail No.
Setting range
Refer to the text
Setting method
Each axis
Setting method
Each axis
Ver.
A0
1 SERVO PARAMETER DETAILS
1.4 Extension setting servo parameters group ([Pr. PC_ _ ])
Ver.
A0
Ver.
Refer to the relevant detail No.
1
79

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-j5w-g

Table of Contents