[Pr. PC29.5_[AL. 0E3 Absolute position counter warning] selection]
Initial value
1h
Setting digit (BIN)
_ _ _ x
_ _ x _
_ x _ _
x _ _ _
1 SERVO PARAMETER DETAILS
82
1.4 Extension setting servo parameters group ([Pr. PC_ _ ])
Setting range
Refer to the text
Functions
[AL. 0E3 Absolute position counter warning] selection
0: Disabled
1: Enabled
While this servo parameter is set to "0" (disabled), [AL. 0E3] does not occur
even when the rotation amount exceeds the maximum value of the multi-
revolution counter or falls below the minimum value.
Set this servo parameter to "0" (disabled) when configuring the absolute
position detection system in cyclic synchronous mode with a motion module
manufactured by Mitsubishi Electric.
While the infinite feed function ("2" (degree unit) in [Pr. PT01.2 Unit for
position data]) is used, [AL. 0E3.1 Multi-revolution counter travel distance
excess warning] does not occur even when this servo parameter is set to "1"
(enabled).