[Pr. PB14_Notch shape selection 1 (NHQ1)]

Initial value
00000000h
[Pr. PB14.1_Notch depth selection 1]
Initial value
0h
0: -40 dB
1: -14 dB
2: -8 dB
3: -4 dB
[Pr. PB14.2_Notch width selection 1]
Initial value
0h
0: α = 2
1: α = 3
2: α = 4
3: α = 5

[Pr. PB15_Machine resonance suppression filter 2 (NH2)]

Initial value
4500 [Hz]
Set the notch frequency of the machine resonance suppression filter 2.
When [Pr. PA08.0 Gain adjustment mode selection] is set to "5" (quick tuning mode), the setting value of this servo parameter
reflects the adjustment result of quick tuning.
When [Pr. PB16.0 Machine resonance suppression filter 2 selection] is set to "1" (enabled), set the notch frequency with this
servo parameter.
Setting range
Refer to the relevant detail No.
Setting range
Refer to the text
Setting range
Refer to the text
Setting range
10 to 9000
Setting method
Each axis
Ver.
A0
Ver.
A0
Setting method
Each axis
1 SERVO PARAMETER DETAILS
1.3 Gain/filter setting servo parameters group ([Pr. PB_ _ ])
Ver.
Refer to the relevant detail No.
Ver.
A0