[Pr. PB45.2_Notch depth selection]
Initial value
0h
Refer to the following table for details.
Setting value
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
[Pr. PB46_Machine resonance suppression filter 3 (NH3)]
Initial value
4500 [Hz]
Set the notch frequency of the machine resonance suppression filter 3.
When [Pr. PB47.0 Machine resonance suppression filter 3 selection] is set to "1" (enabled), set the notch frequency with this
servo parameter.
Setting range
Refer to the text
Setting range
10 to 9000
Ver.
A0
Depth [dB]
-40.0
-24.1
-18.1
-14.5
-12.0
-10.1
-8.5
-7.2
-6.0
-5.0
-4.1
-3.3
-2.5
-1.8
-1.2
-0.6
Setting method
Each axis
1 SERVO PARAMETER DETAILS
1.3 Gain/filter setting servo parameters group ([Pr. PB_ _ ])
Ver.
A0
1
57