[Pr. PD60.0_DI pin polarity selection]
Initial value
0h
Select the DI pin polarity.
Setting digit (BIN)
_ _ _ x
_ _ x _
_ x _ _
x _ _ _
[Pr. PD60.1_DI pin polarity selection]
Initial value
0h
Select the DI pin polarity.
Setting digit (BIN)
_ _ _ x
_ _ x _
_ x _ _
x _ _ _
[Pr. PD60.2_For manufacturer setting]
This servo parameter is for manufacturer setting.
[Pr. PD60.3_For manufacturer setting]
This servo parameter is for manufacturer setting.
[Pr. PD60.4_For manufacturer setting]
This servo parameter is for manufacturer setting.
[Pr. PD60.5_For manufacturer setting]
This servo parameter is for manufacturer setting.
[Pr. PD60.6_For manufacturer setting]
This servo parameter is for manufacturer setting.
[Pr. PD60.7_For manufacturer setting]
This servo parameter is for manufacturer setting.
Setting range
Refer to the text
Functions
DI pin polarity selection 1
0: ON with 24 V input
1: ON with 0 V input
DI pin polarity selection 2
0: ON with 24 V input
1: ON with 0 V input
DI pin polarity selection 3
0: ON with 24 V input
1: ON with 0 V input
DI pin polarity selection 4
0: ON with 24 V input
1: ON with 0 V input
Setting range
Refer to the text
Functions
DI pin polarity selection 5
0: ON with 24 V input
1: ON with 0 V input