[Pr. PF34_Machine diagnosis function selection (*MFP)]
Initial value
00000000h
[Pr. PF34.0_Friction failure prediction warning selection]
Initial value
0h
0: Disabled
1: Enabled (automatic threshold setting)
2: Enabled (manual threshold setting)
3: Threshold reset
When "2" is set, if the dynamic friction exceeds the set threshold, [AL. 0F7.2 Friction failure prediction warning] will occur.
When "3" is set, the setting of the servo parameter will change to "1" automatically after the threshold is reset.
[Pr. PF34.1_Vibration failure prediction warning selection]
Initial value
0h
0: Disabled
1: Enabled (automatic threshold setting)
2: Enabled (manual threshold setting)
3: Threshold reset
When "2" is set, if the vibration level exceeds the set threshold, [AL. 0F7.1 Vibration failure prediction warning] will occur.
When "3" is set, the setting of the servo parameter will change to "1" automatically after the threshold is reset.
[Pr. PF34.2_Servo motor total travel distance failure prediction warning selection]
Initial value
0h
0: Disabled
1: Enabled
2: Servo motor total travel distance reset
When "1" is set, if the value of the servo motor total travel distance + [Pr. PF47 Servo motor total travel distance offset]
exceeds the value of [Pr. PF41 Failure prediction - Servo motor total travel distance], [AL. 0F7.3 Servo motor total travel
distance failure prediction warning] will occur.
When "2" is set, the setting of the servo parameter will change to "1" automatically after the servo motor total travel distance
reset.
1 SERVO PARAMETER DETAILS
124
1.7 Extension setting 3 servo parameters group ([Pr. PF_ _ ])
Setting range
Refer to the relevant detail No.
Setting range
Refer to the text
Setting range
Refer to the text
Setting range
Refer to the text
Setting method
Each axis
Ver.
A0
Ver.
A0
Ver.
A0
Ver.
Refer to the relevant detail No.