5. PARAMETERS
5.1.5 Forced stop input selection
No.
Symbol
PA04 *AOP1 Function selection A-1
www.DataSheet4U.com
The servo forced stop function is voidable.
When not using the forced stop (EM1) of servo amplifier, set the selection of servo forced stop to Invalid (
1). At this time, the forced stop (EM1) automatically turns on inside the servo amplifier.
Parameter
Name
POINT
This parameter is made valid when power is switched off, then on after
setting, or when the controller reset has been performed.
Parameter No.PA04
0
0
0
Selection of servo forced stop
0: Valid (Forced stop (EM1) is used.)
1: Invalid (Forced stop (EM1) is not used.)
Initial Value
5 - 4
Unit
Setting Range
0000h
Refer to the text.