2–58
SelectSet Avantra Series Control Panel and Operating Guide
4. At the end of the communication, the diagnostic computer signals
the imagesetter to reboot.
5. If the imagesetter operating software can complete the reboot in
spite of the error, the Run screen appears on the control panel
showing no activity, which indicates the imagesetter is in Idle
mode, waiting to run a job.
If the imagesetter detects a fatal error when Auto Dial Out is off,
follow the recovery procedures provided with the error messages in
Chapter 4: Diagnostic and Error Messages.
Note: Keep in mind that, during long periods of unattended
operation, whether Auto Dial Out is on or off, it is possible for the
imagesetter to be halted by a fatal error that requires operator
intervention.
In the case of recurring fatal errors, you can attempt to turn off Auto
Dial Out as follows:
1. During the four-second delay before the imagesetter reboots to
dial out, turn off the imagesetter. Use the power switch to the left
of the control panel.
2. Wait a few minutes, then restart the imagesetter.
3. If the imagesetter can boot up, turn off Auto Dial Out.
The example in the preceding section, Using Configuration Functions,
shows how to select the Auto Dial Out mode. Use the procedure in that
section to turn Auto Dial Out off.