Cleaning Avantra 30 Punch Trays

Check the punch trays every three months. There are two punch trays
on the Avantra 30. Perform the following procedure to empty them.
1. Turn off the imagesetter.
2. Remove the front access panel.
3. One punch tray is attached to the front of the take-up light shield.
It is bright red. Lift the tray up slightly and then pull it down to
remove it. Empty the tray.
1
2
3
Figure 5.6 The Avantra 30 imagesetter with the front access panel off.
—The light shield. —The front punch tray. —The rear punch tray.
4.
Replace the tray and replace the front access panel.
5.
Open the left bottom side door by swinging it out at a right angle to
the imagesetter. The punch tray is located toward the back of the
imagesetter. See Figure 5.6.
6.
Gently slide the red tray out. Empty it and slide it back in.
7.
Close the side door and restart the imagesetter.