SelectSet Avantra Series Control Panel and Operating Guide

Setting the Imaging Exposure

You must specify an exposure setting (density range) for each resolu-
tion that you use.
The steps for selecting the exposure are:
#
1. Select resolution:
1200, 1800, 2400
or 3600 dpi
dpi
3. Accept or cancel:
Note: You must run exposure tests to determine the optimum
exposure setting for your work. Run tests for each media type and
each imaging resolution before you begin production.
Note: The Avantra 25E does not have the 3600 dpi setting. As a
result, 3600 dpi is not an available selection for resolution.
See Chapter 3: Running Exposure Tests in this user guide for informa-
tion on running and evaluating test pages.
A
F F
#1
B ?
?
?
3600
2400
1800
1200
dpi
2. Adjust exposure:
Density Range:
0 to 1430
4. Repeat as needed:
Adjust exposure for other
resolutions as required.
dpi
802
752
711
698