44 Cut Not Allowed
Not enough media has been fed past the cutter.
If this message appears when you use Cut in the
Utilities screen, follow the Overriding Error 44: Cut Not
Allowed procedure later in this section.
45 Feed and Cut Before Changing
Supply
A media supply is already loaded and media from that
supply has been imaged and advanced into the take-up
cassette.
Feed and cut the media and remove the take-up
cassette. Unload the current supply, then load the other
supply.
46 Laser Bad
Hardware error.
Reset. Call for service if the error persists.
47 Carriage Speed Error
Motion of the carriage has been blocked.
Open the side panel to determine the problem. This
error is usually caused by a crinkle in the media. Use
Unload to clear the error.
48 Invalid Engine Configuration
Hardware error.
Reset. If the error persists, call for service.