78 Media Jam at Processor Entry Roller
Media passed the first processor input sensor but did
not reach the second processor input sensor.
Remove media from the entry roller area of the processor.
Reset. If the error persists, call for service.
79 Media Load Is Not Allowed
An attempt was made to load media into the drum
A
B
while some media still remains in the drum. (The
?
supply-side drum sensor reports media is present. The
take-up cassette side (media exit) drum sensor reports
no media is present.)
Unload media from the currently loaded supply cas-
sette. Access the drum area and verify that both supply
cassettes are unloaded. If a cassette is still loaded,
manually clear the media from the drum area. Then,
make sure the leading edge of the media is correctly
positioned at the "fingers" of each supply cassette.
Reset and load one of the supply cassettes. If the error
persists, call for service.
80 Bridge Is Not In Light Mode
An attempt was made to raise the bridge while the
bridge foot is attached and the bridge is in heavy mode.
Use the Bridge Shuttle/Weight icon on the Utility screen
to shift the bridge weight into light mode and continue.
See the Correcting Error 80: Bridge Is Not In Light
Mode section later in this chapter for detailed instruc-
tions on how to correct this error condition.
4–24
SelectSet Avantra Series Control Panel and Operating Guide