5–2
SelectSet Avantra Series Control Panel and Operating Guide

Universal Maintenance Procedures

To maintain any SelectSet Avantra imagesetter, you only need to keep
it clean. For all models of the SelectSet Avantra imagesetter:
Keep your work area as clean as possible.
Clean the parts of the imagesetter as indicated in the following
table.
In addition, refer to the section Model-Specific Procedures later in
this chapter for specific maintenance information on each mode.

Table of Universal Maintenance Procedures

Part
External panels
Control panel
Take-up cassette
compartment
Take-up cassette
exterior and interior
Supply cassette
compartment
Supply cassette
exterior and interior
Supply rollers
Interval
Cleaning Method
As required
Wipe with a damp cloth. Use a mild
soap as a cleaning agent, if necessary.
As required
Wipe with a damp cloth.
Every two weeks
Vacuum or wipe with a clean, dry, lint-
free cloth. Do not use cleaning agents
of any kind. When vacuuming, use a
clean attachment with soft bristles. Do
not use metal or hard plastic
attachments.
Once a month
Vacuum or wipe clean as described
above. Open the take-up cassette by
removing the six screws that hold the
lid and base together.
Every two weeks
Vacuum or wipe with a clean, dry, lint-
free cloth. Do not use cleaning agents
of any kind. When vacuuming, use a
clean attachment with soft bristles. Do
not use metal or hard plastic
attachments.
Every time you
Vacuum or wipe clean as described
load media
above.
Once a week
Remove supply cassettes. Wrap plastic
packing tape around your hand with
the sticky side out and press it against
the rollers to pick up dirt. You can also
use adhesive rollers used for removing
lint from clothing. See Figure 5.1.