Figure 5.5 Opening the right side top door. —The thumbscrew.
The filter is located on the inside back panel of the side door. Pull
out the filter and vacuum it.
Replace the Drum Intake filter. This filter is approximately
3/4 in. (19 mm) thick and is made of several different layers.
Interval: Once a month or more frequently if necessary.
Method for imagesetters not connected to an OLP: Shut down the
imagesetter. From the rear of the imagesetter, pull out the filter
and replace it.
Method for imagesetters connected to an OLP: Shut down the
imagesetter. Open the center bottom panel on the right side of the
OLP. Look to the left. You will see two large hoses that resemble
dryer hoses. Remove the bottom hose by unscrewing the 4
wingnuts that attach it. Pull the hose off. Pull out the filter and
replace it. Reattach the hose.
For both methods, use part number C00305-001. Contact your
service provider for information about ordering replacement
filters.