74 Foot Not Attached
An attempt was made to put the bridge into light mode
when the bridge foot is already removed.
It is not necessary to use Bridge Shuttle/Weight to put
the bridge into light mode if the bridge foot is not
attached.
Clear the error code. Continue with the task in process.
75 Bridge Communication Overflow
An error occurred in communication between the
imagesetter and the bridge.
Reset. If the error persists, call for service.
76 Media Jam in Bridge
Media passed the bridge center sensor but did not reach
the bridge exit sensor.
Remove the media from the bridge area.
Reset. If the error persists, call for service.
77 Media Jam in Bridge
Media entered the bridge but did not reach the first
processor input sensor in the expected amount of time.
Remove the media from the bridge area.
Reset. If the error persists, call for service.