Opening of the poppet causes the pressure in chamber A to fall and the plunger to open. As the
result the pressurized oil at port P runs into tank passage (T).
Tank passage
T
P
Housing
passage
(4)
The pressure at port P becomes lower than set pressure of the spring, the poppet is seated by
spring force. Then the pressure at port P becomes equal to set pressure of the spring and the
plunger is seated to the socket.
P
Housing
passage
Chamber A
Tank
Plunger
T
Socket
Tank
Plunger
T
2-45
Poppet
Poppet
Spring
14W92MC43