DTC
HCESPN FMI
Mounting pressure sensor (HCESPN 128 or 205)
(Detection)
(When Boom Down Pilot Pressure Cutoff Solenoid is Off)
10 seconds continuous,
Boom Down Pilot Pressure Cutoff Solenoid drive unit
4
Measurement Voltage ≤ 3.0V
(Cancellation)
(When Boom Down Pilot Pressure Cutoff Solenoid is Off)
3 seconds continuous,
Boom Down Pilot Pressure Cutoff Solenoid drive unit
Measurement Voltage > 3.0V
(Detection)
220
(When Boom Down Pilot Pressure Cutoff Solenoid is On)
10 seconds continuous, Boom Down Pilot Pressure Cutoff Solenoid drive
current > 6.5 A
6
(Cancellation)
(When Boom Down Pilot Pressure Cutoff Solenoid is On)
3 seconds continuous, Boom Down Pilot Pressure Cutoff Solenoid drive
current ≤ 6.5 A
(Results / Symptoms)
1. Control Function – Boom floating control operation failure
(Checking list)
1. CD-369 (#1) – CN-53 (#35) Checking Open/Short
2. CD-369 (#2) – CR-35 (#87) Checking Open/Short
Monitor – Selecting attachment(breaker / crusher)
(Detection)
(When ATT Relief Setting EPPR 1 Current is equal or more than 10 mA)
5
10 seconds continuous, ATT Relief Setting EPPR 1 drive current = 0 mA
(Cancellation)
ATT Relief Setting EPPR 1 Current is equal or more than 10 mA)
3 seconds continuous, ATT Relief Setting EPPR 1 drive current ≥ 10 mA
(Detection)
221
10 seconds continuous, ATT Relief Setting EPPR 1 drive current > 1.0 A
6
(Cancellation)
3 seconds continuous, ATT Relief Setting EPPR 1 drive current ≤ 1.0 A
(Results / Symptoms)
1. Control Function – Option attachment flow control – P1 relief pressure setting failure
(Checking list)
1. CD-365 (#2) – CN-53 (#39) Checking Open/Short
2. CD-365 (#1) – CN-53 (#40) Checking Open/Short
Some error codes are not applied to this machine.
G : General
C : Crawler Type
Diagnostic Criteria
W : Wheel Type
5-32
Application
G
C
W

Hide quick links: