DTC
HCESPN FMI
(Detection)
(When Pump EPPR Current is more than 10 mA)
10 seconds continuous, Pump EPPR drive current < 0 mA
5
(Cancellation)
(When Pump EPPR Current is more than 10 mA)
3 seconds continuous, Pump EPPR drive current ≥10 mA
(Detection)
10 seconds continuous, Pump EPPR drive current > 1.0A
6
140
(Cancellation)
3 seconds continuous, Pump EPPR drive current ≤ 1.0 A
(Results / Symptoms)
1. Control Function – Pump horse power setting specification difference
(Checking list)
1. CN-75 (#2) – CN-52 (#9) Checking Open/Short
2. CN-75 (#1) – CN-52 (#10) Checking Open/Short
(Model Parameter) mounting Boom Priority EPPR
(Detection)
(When Boom Priority EPPR Current is more than 10 mA)
5
10 seconds continuous, Boom Priority EPPR drive current < 0 mA
(Cancellation)
(When Boom Priority EPPR Current is more than 10 mA)
3 seconds continuous, Boom Priority EPPR drive current ≥ 10 mA
(Detection)
141
10 seconds continuous, Boom Priority EPPR drive current > 1.0 A
6
(Cancellation)
3 seconds continuous, Boom Priority EPPR drive current ≤ 1.0 A
(Results / Symptoms)
1. Control Function – Boom first control operation failure
(Checking list)
1. CN-133 (#2) – CN-52 (#34) Checking Open/Short
2. CN-133 (#1) – CN-52 (#35) Checking Open/Short
Some error codes are not applied to this machine.
G : General
C : Crawler Type
Diagnostic Criteria
(Fuel efficiency/speed specification failure)
W : Wheel Type
5-23
Application
G
C
W