Part name
Relay
CR-2
CR-9
CR-85 CR-95 CR-101
CN-66
Solenoid valve
CN-88
CN-149 CN-237 CN-262
CN-263 CN-367 CN-368
CN-369 CN-370 CN-419
CN-420 CN-421
EPPR valve
CN-75 CN-133 CN-242
CN-309 CN-310 CN-365
CN-366 CN-378
Speaker
CN-23(LH)
Switch
(locking type)
CS-52
CS-52
CS-73A
Room lamp
Symbol
30
87a
87
85
86
87
85
30
86
87a
CR-4
CR-5
CR-7
CR-13 CR-35 CR-36
1
2
CN-68
CN-70
CN-135 CN-140
1
2
CN-75 CN-133 CN-238
CN-239 CN-240 CN-241
CN-242
1
2
CN-24(RH)
CS-67
CS-99
CS-67
CS-73
CS-99
3
2
1
CL-1
Specifications
24V 16A
24V 1A
700mA
20W
86 2dB
24V 1.5A
24V 10W
4-24
Check
Check resistance
Normal : About 160
(for terminal 85-86)
0 (for terminal 30-87a)
(for terminal 30-87)
Check resistance
Normal : 15~25
(for terminal 1-2)
Check resistance
Normal : 15~25
(for terminal 1-2)
Check resistance
Normal : A few
Check contact
Normal
ON : 0
(for terminal 7-3)
(for terminal 7-9)
OFF :
(for terminal 7-3)
0
(for terminal 7-9)
Check disconnection
Normal : 1.0
ON : 0 (For terminal 1-2)
(For terminal 1-3)
OFF :
(For terminal 1-2)
0 (For terminal 1-3)