EPPR VALVE CHECK PROCEDURE
EPPR VALVE CHECK PROCEDURE
2)
2)
(1)
(1)
Check electric current value at EPPR
Check electric current value at EPPR
valve
valve
①
Disconnect connector CN-133 from
EPPR valve.
②
Insert the adapter to CN-133 and install
multimeter as figure.
③
Start engine.
④
Set S-mode and cancel auto decel
mode.
⑤
If rpm display approx 1750 ± 50 rpm
disconnect one wire harness from EPPR
valve.
⑥
Check electric current in case of
combined boom up and swing operation.
(2)
(2)
Check pressure at EPPR valve
Check pressure at EPPR valve
①
Remove hose from A5 port and connect
pressure gauge as figure.
·Gauge capacity : 0 to 50 kgf/cm
②
Start engine.
③
Set S-mode and cancel auto decel
mode.
④
If rpm display approx 1750 ± 50 rpm
check pressure (In case of combined
boom up and swing operation).
⑤
If pressure is not correct, adjust it.
⑥
After adjust, test the machine.
2
(0 to 725 psi)
Spec : 400~600 mA
(combined boom up and swing operation)
Boom priority
EPPR valve
CN-133
Adapter
(P/no.:21Q6-50410)
12~37 kgf/cm (170~530 psi)
(combined boom up and swing operation)
Pressure
gauge
A4
Boom priority
EPPR valve
5-58
Safety solenoid valve
Solenoid valve
Block
Multimeter
145ZF5MS15
Safety solenoid valve
Solenoid valve
Block
145ZF5MS16