Hyundai HX145LCR Manual page 420

Hide thumbs Also See for HX145LCR:
Table of Contents

Advertisement

14. MALFUNCTION OF POWER MAX
14. MALFUNCTION OF POWER MAX
·
Fault code : HCESPN 166, FMI 4 or 6
Before carrying out below procedure, check all the related connectors are properly inserted.
1) 1)
INSPECTION PROCEDURE
INSPECTION PROCEDURE
Check resistance
YES
between CN-51
(18)-GND
Is voltage between
CN-88(2)-GND
SPEC : Power max button pressed ON : 0Ω
normal?
SPEC
Starting switch ON :
24±1V
NO
Starting switch OFF :
0V
See TEST 18
Wiring diagram
Wiring diagram
MCU
2
CN-52
18
CN-51
CS-26
1
2
POWER MAX SWITCH
Check resistance
YES
between CN-88
(1)-(2)
SPEC: 15-35Ω
See TEST 19
NO
Power max button released OFF : ∞ Ω
6
5
CN-4
YES
NO
6-65
Cause
Remedy
Short circuit or poor
Repair or replace
connection between
CN-88(1)-CN-52 (2)
Defective power
Repair or replace
max. solenoid valve
Check hydraulic
system
Short circuit or poor
Repair or replace
connection between
CN-51(18)-CS-26
Short circuit or poor
Repair or replace
connection between
CN-88(2)-
Fuse No. 24
CN-88
1
2
POWER MAX SOLENOID
FUSE
NO.24
145LCR6MS03