Hyundai HX145LCR Manual page 295

Hide thumbs Also See for HX145LCR:
Table of Contents

Advertisement

DTC
HCESPN FMI
10 seconds continuous, Travel Forward Press. Sensor Measurement
0
Voltage > 5.2V
10 seconds continuous, 0.3V≤ Travel Forward Press. Sensor Measurement
1
Voltage < 0.8V
10 seconds continuous, Travel Forward Press. Sensor Measurement
4
Voltage < 0.3V
(Results / Symptoms)
530
1. Monitor – Travel Forward Press. display failure
2. Control Function – Driving interoperability power control operation failure
(Checking list)
1. CD-73 (#B) – CN-54 (#6) Checking Open/Short
2. CD-73 (#A) – CN-54 (#3) Checking Open/Short
3. CD-73 (#C) – CN-54 (#13) Checking Open/Short
10 seconds continuous, 0.3V≤ Travel Reverse Press. Sensor Measurement
1
Voltage < 0.8V
10 seconds continuous, Travel Reverse Press. Sensor Measurement
4
Voltage < 0.3V
(Results / Symptoms)
1. Monitor – Travel Reverse Press. display failure
531
2. Control Function – Driving interoperability power control operation failure
(Checking list)
1. CD-74 (#B) – CN-54 (#23) Checking Open/Short
2. CD-74 (#A) – CN-54 (#3) Checking Open/Short
3. CD-74 (#C) – CN-54 (#13) Checking Open/Short
0
10 seconds continuous, Battery input Voltage > 35V
1
10 seconds continuous, Battery input Voltage < 18V
(Results / Symptoms)
705
1. Control Function – Startup impossibility
(Checking list)
1. CS-74A (#1) – CN-51 (#1) Checking Open/Short
(When Engine is equal or more than 400 rpm) 10 seconds continuous,
1
Alternator Node L Measurement Voltage < 18V
(In case 12v goods, Alternator Node L Measurement Voltage < 9V)
707
(Results / Symptoms)
1. Control Function – Battery charging circuit failure
(Checking list)
1. CS-74A (#1) – CN-51 (#2) Checking Open/Short
Some error codes are not applied to this machine.
G : General
Diagnostic Criteria
C : Crawler Type
W : Wheel Type
5-37