SELF DIAGNOSIS FUNCTION
SELF DIAGNOSIS FUNCTION
(1) (1)
Procedure
Procedure
Press the air recirculation button over 5 times within
2 seconds during pressing the AUTO switch
Cancelled diagnosis function(normal function)
(2) (2)
Error check
Error check
·
The corresponding error code flickers on the setup temperature display panel, the other symbol
will turn OFF.
·
Error code flickers every 0.5 second.
·
If error code is more than two, each code flickers 2 times in sequence.
·
Error code
Error code
11
12
14
15
(3) (3)
Fail safe function
Fail safe function
Error description
Cabin inside sensor (11)
Ambient sensor (12)
Duct (evaporator) sensor (14)
Temp actuator (15)
Mode actuator 1, 2 (16, 17)
Starting switch ON
All symbol of LCD blink 5 times
Error check
Press AUTO switch
Description
Cabin inside sensor
Ambient sensor
Duct (evaporator) sensor
Temp actuator
25˚C alternate value control
20˚C alternate value control
1˚C alternate value control
If opening amount is 0 %, the alternate value is 0 %
If not, the alternate value is 100 %
The alternate value is vent
5-94
Switch OFF
System OFF
Error code
16
17
18
-
Fail safe function
3607A3CD69
Description
Mode actuator 1
Mode actuator 2
Intake actuator
-