P2 SIDE
P2 SIDE
The hydraulic fluid from pump A1 flows into the main control valve through the inlet port "P2", into
the P2 bypass passage and P2 parallel passage.
The hydraulic fluid from the pump A1 is directed to the tank through the bypass passage of
spools : travel right, swing, boom 2 & swing priority, arm 1, option "B" and option "C" (dozer), the
negative relief valve of P2, tank passage and the tank port "T1".
Straight travel spool
B
A
TRAVEL(RH)
SWING
BOOM 2 &
SW PRIORITY
ARM 1
OPTION-B
OPTION-C
(DOZER)
P2 Bypass passage
P2 port
P2 Parallel passage
SECTION A-A
SECTION B-B
2-24
Tank port T1
B
P2 Bypass passage
A
Tank passage