Hyundai HX145LCR Manual page 407

Hide thumbs Also See for HX145LCR:
Table of Contents

Advertisement

2) 2)
TEST PROCEDURE
TEST PROCEDURE
Test 11
Test 11 : Check voltage at CN-52 (32)
(1)
(1)
and ground.
Prepare 1 piece of thin sharp pin, steel or
copper.
Insert prepared pin to rear side of
connectors : One pin to (32) of CN-52.
Starting switch ON.
Check voltage as figure.
SPEC : Actuator operating : 1~5 V
CN-51
10
9
8
7
6
20
30
40
39
38
37
36
6-52
MCU
PIN
CN-52
5
4
3
2
1
CN-52
Female
11
21
32
34
33
32
31
GROUND
Multimeter
300L6MS10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents